Sold

ABAR-IPSEN MODEL VR 60772 BOTTOM LOADING VACUUM FURANCE (11663)

FURNACES, VACUUM
Manufacturer:
ABAR-IPSEN
Model:
_UNKNOWN_
Condition:
Good
Stock #:
11663
ABAR-IPSEN MODEL VR 60772 BOTTOM LOADING VACUUM FURANCE (11663)

MACHINE #11663

MANUFACTURER: ABAR-IPSEN

TYPE: BOTTOM LOAD VACUUM FURNACE

SIZE I.D.: 60"DIA X X 72"H

SIZE O.D.: 15'W X 22'L X 19.5'H

MODEL: VR-60X72

SERIAL NUMBER: BM1126

MAXIMUM TEMP.: 2400 F

ELECTRICS: 460 VOLTS, 485 KVA, 3 PHASE (APPROX. 400 KW HEATERS)

CONTROLS: HONEYWELL DIGITAL TEMPERATURE CONTROL, HONEYWELL
OVERTEMPERATURE CONTROL, HONEYWELL STRIP CHART
RECORDER AND LEYBOLD HERAEUS VACUUM CONTROLS MOUNTED
IN ENCLOSED TWO DOOR PANEL

GENERAL: STANDARD IPSEN BOTTOM LOAD DESIGN WITH MOLYBDENUM
LINER AND GRAPHITE FLAT BAR HEATING ELEMENTS.
PUMPING SYSTEM INCLUDES STOKES 412 MECHANICAL PUMP,
ROOTS 615 BOOSTER AND VARIAN 20" DIFFUSION PUMP.
LOAD CAR BOTTOM OF FURNACE IS RAISED AND LOWERED
BY (4) JACK SCREWS. ONCE ON GROUND CAR IS
ELECTRICALLY MOVED AWAY FOR LOADING AND UNLOADING.
HEATING ELEMENTS ARE IN THREE ZONES
(BOTTOM,MIDDLE,TOP) AND ARE CONTROLLED THROUGH
VRT'S. AT END OF HEAT CYCLE FURNACE IS BACK FILLED
WITH NITROGEN WHICH IS CIRCULATED BY AN EXTERNALLY
MOUNTED 50 HP 4400 CFM BLOWER THROUGH A WATER COOLED
HEAT EXCHANGER AND BACK INTO THE FURNACE. INCLUDED
IS A NITROGEN STORAGE TANK,WATER STORAGE TANK
WITH PUMP, GASOLINE ENGINE BACK UP (FOR WATER
PUMP IN THE EVENT OF ELECTRIC POWER LOSS) AND
OUTSIDE WATER COOLER.

**PRICE QUOTED AS IS WHERE IS SUBJECT TO PRIOR SALE**

**ALL SPECIFICATIONS ARE SUBJECT TO VERIFICATION BY PURCHASER**