Capacity | 55" | 1,397 mm |
MACHINE # 10671
MANUFACTURER: EBNER INDUSTRIEOFENBAU, AUSTRIA
TYPE FURNACE: BELL ANNEALING GAS FIRED
YEAR OF MANUFACTURE: 1985
MAXIMUM CHARGING (COIL) HEIGHT: 1800mm (5' 11")
MAXIMUM CHARGING (COIL) DIA: 1200mm (3' 11-1/4")
MAXIMUM LOAD ON BASE: 16 METRIC TONS (17.6 U.S. TONS)
MAXIMUM WORKING TEMPERATURE: 850 C (1560 F)
NUMBER OF BURNERS: 3
RATING PER BURNER: 8,7 m3/h (306 cft/h)
TOTAL GAS FLOW: 26 m3/h (918 cft/h)
GAS PRESSURE AT BURNER: 11 mbar (0,16 psi)
TYPE OF GAS: NATURAL GAS
TYPE OF ATMOSPHERE: HYDROGEN/NITROGEN
INCLUDES:
1 FURNACE BELL
2 WORK BASES
2 VALVE STANDS
2 INNER COVERS
1 CRANE ATTACHMENT
1 COOLING BELL
1 VACUUM PUMP UNIT
1 CONTROL CENTER
INSTALLATION ALSO INCLUDES THE FOLLOWING:
-(1) GAS FIRED FURNACE (FURNACE BELL):
MAXIMUM TEMPERATURE 850 DEG. C (1562 DEG. F)
RATING FOR FURNACE: 25 kW
OPERATING PRESSURE: 0,6 BAR
CONNECTED LOAD: 115 KVA
SUPPLY VOLTAGE: 460 VOLT, 3 PH., 60 HZ.
ATMOSPHERE CONSUMPTION: 14 CU. M/H (495 CU. FT./H)
FURNACE NUMBER: 2226
SERIAL NUMBER: 2717
-(1)ELECTRICALLY HEATED COOLING BELL:
MAXIMUM TEMPERATURE: 110 DEG. C (230 DEG. F)
RATING FOR BELL: 0,35kW
VOLTAGE: 115/60 hz
FURNACE NUMBER: 2203
SERIAL NUMBER: 2717
-(1)VACUUM INNER COVER:
INNER COVER DIA.: 1400 mm (55")
CYLINDRICAL BAFFLE DIA.: 1200 mm (47")
EFFECTIVE HEIGHT -
(WITH CHARGING FRAME): 1800 mm (70")
TEMPERATURE CEILING IN
WORKLOAD SPACE: 800 DEG. C (1472 DEG. F)
-(1)VACUUM PUMP: 5.5 kW, 1750 RPM, 480 VOLTS 3 PHASE 60
HERTZ
12.3 AMPS
MANUFACTURER: BUSCH VACUUM PUMPS
-WORKBASE PLUS FAN:
MAXIMUM LOAD ON BASE: 16 TONS (17.7 U.S. TONS)
IMPELLER DIAMETER: 700 mm (27 1/2")
BASE FAN MOTOR: SCHORCH 3 PHASE SQUIRREL-CAGE MOTOR,
TYPE KN5 200 L-WZ 099-Z
RATING: 41/11 KW
SPEED: 1770/875 RPM
VOLTAGE: 3 PHASE, 460 VOLT, 60 HZ
MOUNTING FORM: V9
ENCLOSURE: IP 23
-COOLING BELL WITH AXIAL-FLOW FANS AND WATER SPRAY SYSTEM:
2 AXIAL-FLOW FANS: EBNER TYPE DMF 80 N 104
RATING: 0.9 KW
SPEED: APPROX. 1800 RPM
VOLTAGE: 3 PHASE, 460 VOLT, 60 HZ
-COMBUSTION SYSTEM:
NUMBER OF CONTROL GROUPS: 1
NUMBER OF BURNERS: 3
INDIVIDUAL BURNING RATING: 8.66 m3/H (305 CFT/H)
TOTAL FUEL GAS RATING: 26 m3/H (915 CFT/H)
GAS PRESSURE AT BURNER: 11 mBAR (0.17 psi)
TYPE OF GAS: NATURAL GAS
-1ST ATMOSPHERE GENERATOR:
CAPACITY (M3H U S C)X: 25
FEEDSTOCK: NH3 (AMMONIA)
VOLTAGE: 460/60 HZ
OPERATING PRESSURE: 0,6 BAR
-2ND ATMOSPHERE GENERATOR:
CAPACITY (M3H/H U S C)X 50
FEEDSTOCK: SPO/N2 (HYDROGEN/NITROGEN)
VOLTAGE: 115/60 HZ
OPERATING PRESSURE: 0.4 BAR
SERIAL NUMBER: 2717
-(1)GAS MIXER
-(1)ABSORBER UNIT
-ALL EBNER POWER CABINETS
-ALL EBNER CONTROL CABINETS
-EBNER ATMOSPHERE SYSTEM CONTROL CENTER
**PRICE QUOTED IS EX-WORKS AS IS WHERE IS SUBJECT TO PRIOR SALE**
**ALL SPECIFICATIONS ARE SUBJECT TO VERIFICATION BY PURCHASER**
We use cookies to improve your experience. Privacy Policy.
We use different type of cookies to optimize your experience on our website. You may choose which type of cookies to allow and can change your preferences at any time. Remember that disabling cookies may affect your experience on the website. You can learn more about how we cookies by visiting our Privacy Policy.
These cookies are necessary to the core functionality our website and some of its features, such as access to secure areas.
These cookies are used to enhance the performance and functionality of our website but are nonessential. However, without these cookies, certain functionality may become unavailable.
These cookies gather information to help us understand site usage, measure marketing effectiveness, and personalize your experience.
These cookies enhance ad relevance, prevent repeat ads, ensure proper display, and sometimes tailor ads to your interests.